TM 9-2320-366-20-1
CONTINUITY TEST
(1) Remove two screws, lockwashers, and
terminal lugs TL164 and TL165 from
troop transport alarm switch. Discard
lockwashers.
(2) Lift switch cover on troop transport alarm
switch.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
one terminal of troop transport alarm
switch.
(5) Connect negative (-) probe of multimeter to
second terminal of troop transport alarm
switch.
(6) Position troop transport alarm switch to on
and note reading on multimeter.
(7) If continuity is not present, replace troop
transport alarm switch (para 20-70).
(8) Install terminal lugs TL165 and TL164 on
troop transport alarm switch with two
lockwashers and screws.
(9) Close switch cover on troop transport alarm
switch.
Change 1