TM 9-2320-366-20-1
e13. VOLTS GAGE DOES NOT OPERATE OR IS INACCURATE (CONT)
CAUTION
Read CAUTION
KNOWN INFO
TEST OPTIONS
on following page.
2.
Circuit breaker CB77 OK.
Continuity Test or
STE/ICE-R Test #91
POSSIBLE PROBLEMS
Is continuity present from
REASON FOR QUESTION
Faulty dashboard cable
connector PX10 socket 1 to
assembly.
If continuity is not present,
a known good ground?
Faulty VOLTS gage.
wire 3004 from connector
PX10 socket 1 to terminal
board TB2 position 9 is faulty.
NO
Repair wire 3004 from connector PX10
socket 1 to terminal board TB2 position 9
YES
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
Replace VOLTS gage (para 7-14).
2-356.2
Change 1
|