TM 9-2320-366-20-1
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back or not
capable of making good contact.
CONTINUITY TEST
(1)
Raise cab (TM 9-2320-366-10-1).
(2)
Disconnect connector clamp from WATER
TEMP gage sensor connector, if equipped.
(3)
Disconnect connector P41 from WATER
TEMP gage sensor connector.
(4)
Set multimeter to ohms.
(5)
Connect positive (+) probe of multimeter
to connector PX11 pin 4.
(6)
Connect negative (-) probe of multimeter
to connector P41 and note reading
on multimeter.
(7)
If continuity is not present, go to step 4
of this fault.
(8)
If continuity is present, replace WATER
TEMP gage sensor (para 7-45).
(9)
Connect connector P41 to WATER TEMP
gage sensor connector.
(10)
Connect connector clamp to WATER
TEMP gage sensor connector, if equipped.
(11)
Lower cab (TM 9-2320-366-10-1).