TM 9-2320-366-20-1
e6. ENGINE CRANKS BUT DOES NOT START (CONT)
CAUTION
Read CAUTION
KNOWN INFO
TEST OPTIONS
on following page.
4.
Continuity Test or
Fuel quantity OK.
STE/ICE-R Test #91
Fuel/water separator primed.
Is continuity present from
REASON FOR QUESTION
Air cleaner hose or tube OK.
connector J31pin 5 to
Start inhibit pushbutton switch
If continuity is not present,
ground?
OK.
wire 3015 from connector J31
Relay K19 OK.
pin 5 to terminal board TB2
POSSIBLE PROBLEMS
position 18 on power
distribution panel (PDP) is
Faulty dashboard cable
faulty. If continuity is present,
assembly.
wire 3015 from connector P31
Faulty engine control cable
socket 5 to terminal lug TL29
assembly.
is faulty.
NO
Repair wire 3015 from connector J31 pin 5
to terminal board TB2 position 18 on power
distribution panel (PDP) (para 2-45) or replace
YES
WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
Repair wire 3015 from connector P31
socket 5 to terminal lug TL29 (para 2-45)
or replace engine control cable
assembly (para 7-80).