TM 9-2320-366-20-1
CONTINUITY TEST
(1) Lift dust boot on 24V LOAD terminal stud
on 200 AMP reverse polarity relay.
(2) Remove nut, lockwasher, and terminal lug
TL169 from 24V LOAD terminal stud on
200 AMP reverse polarity relay. Discard
lockwasher.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter
to terminal lug TL169.
(5) Connect negative (-) probe of multimeter to
terminal lug TL167 and note reading on
multimeter.
(6) If continuity is not present, replace 200
AMP terminal block to reverse polarity
relay 24 VDC load cable (para 20-62).
(7) If continuity is present, replace 200 AMP
terminal block to PDP 24 VDC cable (para
20-51).
(8) Position terminal lug TL167 on right 24V
LOAD terminal stud on 200 AMP terminal
block with washer, lockwasher, and nut.
(9) Tighten nut to 15-19 lb-ft (21-25 N.m).
(10) Position terminal lug TL169 on 24V LOAD
terminal stud on 200 AMP reverse polarity
relay with lockwasher and nut.
(11) Tighten nut to 27-33 lb-ft (37-45 N.m).
(12) Position dust boot on 24V LOAD terminal
stud on 200 AMP reverse polarity relay.
Change 1
2-284.23
|