TM 9-2320-366-20-1
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
CONTINUITY TEST
(1) Remove nut and terminal lugs TL39 and
TL10 from battery 24 VDC cable.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter to
terminal lug TL39.
(4) Connect negative (-) probe of multimeter to
terminal lug TL37 and note reading on
multimeter.
(5) If continuity is not present, replace battery
to 200 AMP terminal block 24 VDC cable
assembly (para 20-53).
(6) Position terminal lugs TL36 and TL37 on
left 24V BAT terminal stud on 200 AMP
terminal block with washer, lockwasher,
and nut.
(7) Tighten nut to 15-19 lb-ft (21-25 N.m).
(8) Install terminal lugs TL10 and TL39 on
battery 24 VDC cable with nut.
Change 1
2-284.19
|