TM 9-2320-366-20-1
CONTINUITY TEST
NOTE
Tag terminal lugs and connection points
prior to disconnecting.
(1) Disconnect batteries (para 7-57).
(2) Remove nut, lockwasher, washer, and
terminal lugs TL37 and TL36 from left 24V
BAT terminal stud on 200 AMP terminal
block. Discard lockwasher.
(3) Remove nut, lockwasher, washer, and
terminal lugs TL1 and TL166 from right 24V
BAT terminal stud on 200 AMP terminal
block. Discard lockwasher.
(4) Set multimeter to ohms.
(5) Connect positive (+) probe of multimeter
to left 24V BAT terminal stud on 200 AMP
terminal block.
(6) Connect negative (-) probe of multimeter to
right 24V BAT terminal stud on 200 AMP
terminal block and note reading on
multimeter.
(7) If continuity is not present, replace 200
AMP terminal block (para 20-58).