TM 9-2320-366-20-1
CONTINUITY TEST
(1) Disconnect batteries (para 7-57)
(2) Remove nut, terminal lug TL10, and
terminal lug TL39 from battery 24 VDC
cable.
(3) Loosen clamp on air hose.
(4) Remove air hose from intake air cleaner
boot.
NOTE
Tag all terminal lug and connection points
prior to disconnecting.
(5) Lift terminal cover on 24V BAT terminal
stud on 100 AMP reverse polarity relay.
(6) Remove nut, lockwasher, and terminal lugs
TL1, TL37, and TL36 from 24V BAT
terminal stud on 100 AMP reverse polarity
relay. Discard lockwasher.
(7) Set multimeter to ohms.
(8) Connect positive (+) probe of multimeter
to terminal lug TL37.
(9) Connect negative (-) probe of multimeter to
terminal lug TL39 and note reading on
multimeter.
(10) If continuity is not present, replace battery to
100 AMP reverse polarity relay 24 VDC cable
(para 7-75).
(11) Lift terminal cover on 24V BAT terminal stud
on 100 AMP reverse polarity relay.
(12) Position terminal lugs TL36, TL37, and TL1 on
24V BAT terminal stud on 100 AMP reverse
polarity relay with lockwasher and nut.
(13) Tighten nut to 120-144 lb-in. (14-16 N.m).
(14) Install terminal lug TL39 and terminal lug TL10
on battery 24 VDC cable with nut.
Change 1
2-284.5
|