TM 9-2320-366-20-1
CONTINUITY TEST
(1) Remove circuit breaker CB70 from PDP.
(2) Position master power switch to on
(TM 9-2320-366-10-1).
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter to
relay K2 socket 86 on PDP.
(5) Connect negative (-) probe of multimeter to
circuit breaker CB70 socket 4 on PDP and
note reading on multimeter.
(6) If continuity is not present, go to step 14
of this fault.
(7) Position master power switch to off
(TM 9-2320-366-10-1).
(8) Install circuit breaker CB70 in PDP.
Change 1
2-277
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |