TM 9-2320-366-20-1
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
VOLTAGE TEST
(1) Remove power distribution panel (PDP)
cover (para 16-2).
(2) Set multimeter to volts DC.
CAUTION
When testing to terminal X1 on PDP, ensure
that multimeter probes come in contact with
the outside metal ring. Failure to comply
may result in false troubleshooting test
results.
(3) Connect positive (+) probe of multimeter to
terminal X1 on power distribution panel
(PDP).
(4) Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(5) If 24 VDC is not present, go to step 10 of
this fault.