TM 9-2320-366-20-1
CONTINUITY TEST
(1) Lift dust boot on 12V BAT terminal stud on
200 AMP reverse polarity relay.
(2) Remove nut, lockwasher, and terminal lug
TL173 from 12V BAT terminal stud on 200
AMP reverse polarity relay. Discard
lockwasher.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter
to terminal lug TL173.
(5) Connect negative (-) probe of multimeter to
terminal lug TL171 and note reading on
multimeter.
(6) If continuity is not present, replace 200
AMP terminal block to reverse polarity relay
12 VDC battery cable (para 20-55).
(7) Position terminal lugs TL171 and TL61 on
right 12V BAT terminal stud on 200 AMP
terminal block with washer, lockwasher,
and nut.
(8) Tighten nuts to 15-19 lb-ft (21-25 N.m).
(9) Position terminal lug TL173 on 12V BAT
terminal stud on 200 AMP reverse polarity
relay with lockwasher and nut.
(10) Tighten nut to 108-132 lb-in. (12-15 N.m).
(11) Position dust boot on 12V BAT terminal stud
on 200 AMP reverse polarity relay.
Change 1
2-266.33
|