TM 9-2320-366-20-1
CONTINUITY TEST
(1) Lift dust boot on 12V LOAD terminal stud
on 200 AMP reverse polarity relay.
(2) Remove nut, lockwasher, and terminal
lug TL174 from 12V LOAD terminal stud on
200 AMP reverse polarity relay. Discard
lockwasher.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter
to terminal lug TL172.
(5) Connect negative (-) probe of multimeter to
terminal lug TL174 and note reading on
multimeter.
(6) If continuity is not present, replace 200
AMP terminal block to reverse polarity relay
12 VDC load cable (para 20-49).
(7) Position terminal lug TL172 on right 12V
LOAD terminal stud on 200 AMP terminal
block with washer, lockwasher, and nut.
(8) Tighten nut to 15-19 lb-ft (21-25 N.m).
(9) Position terminal lug TL174 on 12V LOAD
terminal stud on 200 AMP reverse polarity
relay with lockwasher and nut.
(10) Tighten nut to 108-132 lb-in. (12-15 N.m).
(11) Position dust boot on 12V LOAD terminal
stud on 200 AMP reverse polarity relay.