CONTINUITY TEST
(1) Lift dust boot on left 12V LOAD terminal
stud on 200 AMP terminal block.
(2) Remove nut, lockwasher, washer, and
terminal lug TL80 from left 12V LOAD
terminal stud on 200 AMP terminal block.
Discard lockwasher.
(3) Remove nut, lockwasher, washer, and
terminal lug TL172 from right 12V LOAD
terminal stud on 200 AMP terminal block.
Discard lockwasher.
(4) Set multimeter to ohms.
(5) Connect positive (+) probe of multimeter to
left 12V LOAD terminal stud on 200 AMP
terminal block.
(6) Connect negative (-) probe of multimeter to
right 12V LOAD terminal stud on 200 AMP
terminal block and note reading on
multimeter.
(7) If continuity is not present, replace 200 AMP
terminal block (para 20-58).