e3. 12 VDC AND 24 VDC CIRCUITS DO NOT OPERATE (CONT)
KNOWN INFO
TEST OPTIONS
7.
Continuity Test or
Circuit breakers CB70 OK.
STE/ICE-R Test #91
Battery(ies) OK.
Is continuity present from
Cab to chassis ground strap
REASON FOR QUESTION
terminal lug TL56 to
OK.
If continuity is not present,
terminal lug TL57?
POSSIBLE PROBLEMS
PDP to cab ground cable is
faulty. If continuity is present,
Faulty PDP to cab ground
wire 1603 is faulty.
cable.
Faulty dashboard cable
assembly.
NO
YES
Replace PDP to cab
ground cable (para 7-126).
Repair wire 1603 from terminal X3 on PDP
to terminal board TB2 position 1 on PDP
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
2-266.10