CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back or not
capable of making good contact.
CONTINUITY TEST
(1) Remove three screws and washers from
PDP.
(2) Remove three screws from PDP.
(3) Lift PDP outward to gain access.
(4) Set multimeter to ohms.
(5) Connect positive (+) probe of multimeter
to terminal board TB1 position 34.
(6) Connect negative (-) probe of multimeter
connector PX33 socket F1 and note
reading on multimeter.
(7) If continuity is not present, repair wire
1692 from connector PX33 socket F1 to
terminal board TB1 position 34 (para
2-45) or replace WTEC II dashboard cable
assembly (para 7-10).
(8) If continuity is present, repair wire 1692
from terminal board TB1 position 36 and
circuit breaker CB21 socket 2 (para 2-45)
or replace WTEC II dashboard cable
assembly (para 7-10).
(9) Install PDP on dashboard with three
screws.
(10) Install three washers and screws in PDP.
(11) Connect connector PX33 to VIM connector.
(12) Tighten screw in connector PX33.
(13) Install kick panel (para 16-3).
(14) Connect batteries (para 7-57).