TM 9-2320-366-20-1
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back or not
capable of making good contact.
CONTINUITY TEST
(1) Install relay K24 in PDP.
(2) Remove relay K1 from PDP.
(3) Remove instrument panel for access
(para 7-15).
(4) Disconnect connector J43 from connector
P43.
(5) Set multimeter to ohms.
(6) Connect positive (+) probe of multimeter
to connector J43 socket 8.
(7) Connect negative (-) probe of multimeter to
relay K1 socket 87 on PDP and note
reading on multimeter.
(8) If continuity is not present, repair wire 74
from relay K1 socket 87 on PDP and
connector J43 socket 8 (para 2-45) or
replace WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(9) If continuity is present, repair wire 74 from
connector P43 pin 8 to terminal TL33 (para
2-45) or replace start and charging cable
assembly (para 7-132).
(10) Connect connector J43 to connector P43.
(11) Install instrument panel (para 7-15).
(12) Install relay K1 in PDP.
(13) Install power distribution panel (PDP) cover
(para 16-2).
(14) Connect batteries (para 7-57).