TM 9-2320-366-20-1
RESISTANCE TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
relay K24 terminal 86.
(3)
Connect negative (-) probe of multimeter to
relay K24 terminal 85 and note reading on
multimeter.
(4)
If 306-399 ohms resistance is not present,
replace relay K24 (para 7-9).
(5)
Connect batteries (para 7-57).