CONTINUITY TEST
(1) Remove nut, lockwasher, and terminal lug
TL24 from auxiliary starter solenoid.
Discard lockwasher.
(2) Set multimeter to ohms.
(3) Connect positive (+) probe of multimeter
to terminal lug TL24.
(4) Connect negative (-) probe of multimeter to
terminal lug TL26 and note reading on
multimeter.
(5) If continuity is not present, repair wire 14A
from terminal lug TL24 to terminal lug TL26
(para 2-45) or replace start and charging
cable assembly (para 7-132).
(6) If continuity is present, replace auxiliary
starter solenoid (para 7-6).
(7) Install terminal lug TL24 on auxiliary
starter solenoid with lockwasher and nut.
(8) Apply adhesive to auxiliary starter solenoid.
(9) Apply adhesive to solenoid right terminal
stud.
(10) Lower cab (TM 9-2320-366-10-1).
(11) Connect batteries (para 7-57).