Table 2-1. Preventive Maintenance Checks and Services (Cont)
Location
Item
Interval
Item to be
Procedure
Not Fully
No.
Checked or
Mission
Serviced
Capable If:
Semiannual
52
15K SRW
WARNING
CABLE
Cable can become frayed or contain
broken wires. Wear heavy leather gloves
when handling cable. Frayed or broken
wires can injure hands. Failure to
comply may result in injury to personnel.
a.
Spool out 15K SRW cable completely
(TM 9-2320-366-20-2); and inspect for kinks,
sharp bends, abrasions, and broken wires.
b.
Check that there are no more than six
b. More than six
randomly distributed broken wires in any six-
broken wires in a
inch section of cable or three broken wires in
six-inch section
one bundle (breaks 3, 4, 5) in a six-inch
or three broken
section. result
wires in one
bundle in a six-
inch section is
evident.
c.
Kinking, crushing, or any other damage
resulting in distortion of the cable structure.
2-54