7-90.
BATTERIES, TERMINALS, AND CABLES REMOVAL/INSTALLATION (CONT).
(5)
Install two jumper cable assemblies (8)
on four battery posts (9) with four
screws (10) and nuts (11). Tighten nuts
(11) to 84 to 96 lb-in (9-11 NSm).
CAUTION
While tightening nuts, hold screws with
wrench or damage to battery may occur.
NOTE
STE/ICE wire connects to front battery
terminal. There is only one cable connected
to rear terminal.
(6)
Install three positive battery cables (12)
and STE/ICE wire (13) with two
screws (14), lockwashers (15), and
nuts (16) on terminals (17). Tighten
nuts (16) to 12 to 16 lb-ft. (16-22 NSm).