TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
7-88.
FUEL LEVEL SENSOR REMOVAL/INSTALLATION (M978) (CONT).
(5)
Remove fuel level sensor (7) from
tank (8).
NOTE
Step (6) is for Model B only.
(6)
Remove clamp (9) and ground strap (10)
from fuel level sensor (7).
b. Installation
NOTE
Step (1) is for Model B only.
(1)
Install ground strap (1) and clamp (2)
on fuel level sensor (3).
WARNING
Adhesives, solvents, and sealing
compounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If adhesive, solvent,
or sealing compound gets on skin or
clothing, wash immediately with soap and
water.
(1.1) Coat threads of fuel level sensor (3)
with pipe thread sealing compound and
install in tank (3.1).
7-320
Change 3
|