TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
(3)
Lift fuel level sending unit (4) with
gasket (8) out of fuel tank (6).
b. Installation.
WARNING
Adhesives, solvents, and sealing
compounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If adhesive, solvent,
or sealing compound gets on skin or
clothing, wash immediately with soap and
water.
(1)
Coat both sides of gasket (1) with
sealing compound, slide gasket (1) over
float (2) and install on fuel level sending
unit (3).
(2)
Install fuel level sending unit (3) in fuel
tank (4) and aline holes in fuel sending
unit with holes in fuel tank.
(3)
Install ground wire (5) on one of five
screws (6) and install five screws on fuel
level sending unit (3). Tighten five
screws.
Install wire (7) with lockwasher (8) and
(4)
nut (9) on fuel level sending unit (3)
c. Follow-on Maintenance.
(1)
Connect batteries (para 7-91).
(2)
Check operation of fuel sending unit
(TM 9-2320-279-10).
END OF TASK