7-72.1. FIXED WORKLAMPS REMOVAL/INSTALLATION (M984E1) (CONT).
(5) Remove screw (11), nut (12),
bracket (13), and screw (14) from lamp
housing (15) and wire harness (16).
(6) Remove lamp (17) and two wires (4)
from lamp housing (15).
(7) Remove two screws (18) and two
wires (4) from lamp (17).
(8) Remove two wire terminals (20) from
wires (4).
b.
Installation.
(1) Install two wire terminals (1) on
wires (2).
(2) Install two wires (2) in lamp housing (3)
on lamp (4) with screws (5).
(3) Install lamp (4) in lamp housing (3).
(4) Install screw (6) and bracket (7) on
wiring harness (8) and lamp housing (3)
with screw (9) and nut (10).