7-54. OUTRIGGER SWITCH BOX REMOVAL/lNSTALLATlON (M984) (CONT).
(3) Install six wires (6) on two outrigger switches (2) with
six screws (7) and lockwashers (8).
(4) Install outrigger switch box (3) with
four screws (9), lockwashers (10), and
nuts (11).
c. Follow-on Maintenance.
(1) Connect batteries (para 7-91).
(2) Close stowage box
(TM 9-2320-279- 10).
(3) Start engine (TM 9-2320-279-10).
(4) Check outrigger switch operation
(TM 9-2320-354-10).
(5) Shut off engine (TM 9-2320-279-10).
END OF TASK