TM
9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
e. Control Box Connectors Removal.
(1) Loosen six screws (1), brackets (2), and open cover (3).
NOTE
Tag and mark all wires before removing.
q
All connectors are removed the same way. Number of wires will vary.
q
Do steps (2) and (3) for winch remote control connectors.
q
(2) Disconnect cap and chain (4) from winch remote control connector (5).
(3) Remove screw (6) and cap and chain (4) from winch remote control connector (5).
(4) Disconnect cable connectors (7) from connectors (5).
7-175
|