TM
9-2320-279-20-1
Electrical System Maintenance Instructions (Cont]
(3) Install terminal board (6) in control
junction box (5) with two screws (7),
lockwashers (8), and nuts (9).
WARNING
Adhesives, solvents, and sealing
compounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If adhesive, solvent,
or sealing compound gets on skin or
clothing, wash immediately with soap and
water.
(4) Apply silicone adhesive-sealant over screw heads (7).
(5) Install seven wires (10) on
terminal board (6) with five
screws (11).
(6) Install connector (12) on
relay assembly (13).
assembly (13),
lockwasher (15), nut (16),
two wires (17), and nut (18)
in control junction box (5).
(8) Apply silicone
adhesive-sealant over screw
head (14).
(9) Position control junction box (5) on
bracket (19) and install two screws (20),
lockwashers (21), and nuts (22).
(10) Position wire (23) in control junction
box (5) and install nut (24) on elbow (1).
7-163
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |