7-49. CONTROL JUNCTION BOX REMOVAL/INSTALLATION (M978) (CONT).
a. Removal.
(1) Remove fuse (1) from fuseholder (2).
NOTE
Tag and mark wires before disconnecting or removing.
q
Remove plastic cable ties as necessary.
q
(2) Remove two nuts (3), lockwashers (4), fuseholder (2), and two wires (5 and 6) from rotary
switch (7).
(3) Remove two screws (8) and three wires (9) from contact button (10).
(4) Disconnect three connectors (11) and remove cover (12) from control junction box (13).
Matchmark position of contact
button and switches.
(5) Remove two boots (14) from
toggle switches (15) and
remove switches from
cover (12). Remove two
nuts (16) from switches.
(6) Remove contact button
cover (17) and contact
button (10) from cover (12).
(7) Remove screw (18),
lockwasher (19), knob (20),
nut (21), and
lockwasher (22) from rotary
switch (7) and remove switch from cover (12).
7-158