Fuel System Maintenance Instructions (Cont)
(7) Remove wingnut (11).
(8) Remove secondary element (12) from air
cleaner (3).
b. Service.
(1) Check elements (1 and 2) for bends or
tears. Replace if damaged.
(2) Tap side or end of elements (1 and 2)
against hand to loosen dirt.
WARNING
Compressed air used for cleaning purposes
will not exceed 30 psi (207 kPa). Use only
with effective personal protective
equipment, goggles, shield, and gloves.
(3) Insert air nozzle inside elements (1
and 2) and blow out dust with
compressed air.
(4) Blow dust from outside of elements (1
and 2) by holding air nozzle at least six
inches from elements.
(5) Remove soot or oily vapor with warm
soapy water.
(6) Reverse flush with clean water to rinse.
(7) Allow elements (1 and 2) to air dry.
(8) Brush dust from side and bottom of air
cleaner (3).
(9) Clean dust from dust unloader (4).
4-5