TM 9-2320-279-20-1
Troubleshooting Malfunctions (Cont)
Table 2-9.
Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ARCTIC HEATER KIT
9. ARCTIC HEATER DIAGNOSTIC TROUBLESHOOTING (ORGANIZATIONAL LEVEL) (MODEL B)
(CONT).
Step 27.
Check arctic heater fuel lines.
If arctic heater fuel lines leak, are damaged or kinked, repair leaks or replace
damaged or kinked fuel line (para 20-3) and go to Step 38.
Step 28.
Turn arctic heater on.
Step 29.
Check if arctic heater operates.
If arctic heater operates, go to Step 32.
Step 30.
If Fault Code Retrieval Device (FCRD) is available, clear fault code 050 and go to Step 32.
Step 31.
If Fault Code Retrieval Device (FCRD) is not available, go to Step 44.
Change 7
2-268.7
|