TM 9-2320-279-20-1
Troubleshooting Malfunctions (Cont)
Table 2-9.
Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ARCTIC HEATER KIT
7. ARCTIC HEATER DOES NOT OPERATE (MODEL B) (CONT).
Step 10.
Check voltage on yellow wire at arctic heater harness connector. Place positive (+) probe
at terminal A1. Place negative (--) probe at terminal C3. Turn arctic heater switch on.
If 24 vdc is present, the arctic heater control unit is faulty, notify the supervisor.
If 24 vdc is not present, repair or replace arctic heater harness yellow wire (para
20-3).
Step 11.
If problem has not been solved, notify the supervisor.
Change 7
2-263
|