TM 9-2320-279-20-1
Troubleshooting Malfunctions (Cont)
Table 2-9.
Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ARCTIC HEATER KIT
7. ARCTIC HEATER DOES NOT OPERATE (MODEL B) (CONT).
Step 7.
Remove left heater compartment cover (para 16-11). Check voltage on red/yellow wire at
arctic heater switch. Place positive (+) probe on red/yellow wire at arctic heater switch.
Place negative (--) probe on known good ground.
If 24 vdc is present, go to Step 9.
Step 8.
Remove arctic heater switch fuse (para 20-3). Perform continuity check on fuse.
If continuity is present, repair or replace arctic heater harness red/yellow wire
(para 20-3).
If continuity is not present, replace arctic heater switch fuse (para 20-3).
Change 7
2-261
|