TM 9-2320-279-20-1
Troubleshooting Malfunctions (Cont)
Table 2-9. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
TANKER SYSTEM (CONT)
5. AUXILIARY PUMP WILL NOT PUMP FUEL (CONT).
NOTE
Refer to FO-1, Sheet 4, for M978 Electric Diagram.
Step 2. Remove control junction box cover (para 7-49). Check resistance across APC AUXILIARY
PUMP CONTROL switch terminals when switch is set to ON.
If there is more than zero ohms resistance, replace APC AUXILIARY PUMP
CONTROL switch (para 7-48).
Step 3. Connect batteries (para 7-91). Check for 24 to 30 vdc to APC AUXILIARY PUMP CONTROL
switch. Touch positive (+) probe to terminal with single red wire and negative (-) probe to
vehicle.
If there is 24 to 30 vdc, go to Step 6.
If no voltage, go to Step 4.