Table 2-1. Unit Level Preventive Maintenance Checks and Services
Item
Interval
Item To Be
Procedure
Not Mission
No.
Inspected
Capable If:
19
Semi-
Main Steer-
Check tie rod and drag links for proper
c. Nuts will not torque
ing Gear
Annual
torque. Tighten nuts to 165 to 180 lb-ft (224
to 165 to 180 lb-ft (224
to 244 Nm).
to 244 Nm).
Continued
d.  Check tie rod adjustment. Measure left
d. Minimum clearance
side tie rod to walking beam minimum
is not 2" to 2-1/8".
clearance. Measure right side tie rod to
walking beam minimum clearance. Mini-
mum clearance between 2" to 2-1/8" indi-
cates proper adjustment. If minimum clear-
ance is not 2" to 2-1/8", readjust (paragraph
13-5).
Check steering gear adjustment holes
for dirt and rust. Clean holes and fill with
grease.