9-2320-211-34-2-3
FRAME 3
1.
G o back to swivel valve (1).
2.
S c r e w in and tighten connector (2).
3.
U n c a p and hold hydraulic line (3) in place on connectors (2) as tagged.
T i g h t e n coupling nut (4). Take off tag.
4.
U n c a p and hold hydraulic line (5) in place as tagged. Tighten coupling
n u t ( 6 ) .  T a k e off tag.
5.
U n c a p and hold four hydraulic lines (7) in place as tagged. Tighten four
coupling nuts (8). Take off tags.
NOTE
F o l l o w - o n Maintenance Action Required:
1.
F i l l hydraulic reservoir.  R e f e r to LO 9-2320-211-12.
2.
C h e c k swivel valve for proper operation. Refer to
T M 9-2320-211-10.
END OF TASK