TM 9-2320-211-34-2-3
FRAME 12
Put gasket (1) and cover (2) in place.
1.
Put in four screws (3) and lockswashers (4).
2.
Press seal (5) into cap (6).
3.
Put gasket (7) and cap (6) with seal (5) in place.
4.
Put in four screws (8) and lockwashers (9).
5.
Fasten dial indicator to housing (10) so that plunger of dial gage is against end of
6.
output shaft (11) as shown.
7.
P u s h in and pull out output shaft (11) to check that end play is between 0.010
i n c h and 0.033 inch.
Take off dial indicator.
8.
If end play is not within limits given in step 7, do steps 10 through 13. If end play
9.
is within given limits, go to frame 13.
Take out four screws (8) and lockwashers (9).
1 0.
Take off cap (6) with seal (5).
11.
Put on another gasket (7). Put cap (6) with seal (5) back in place.
1 2.
Do steps 5 through 12 again until end play is within given limits.
1 3.
G o TO FRAME 13
17-760
|