TM
9-2320-211-34-2-3
c.
Cleaning, Inspection, and Repair.
WARNING
D r y cleaning solvent is flammable. Do not use
near an open flame. K e e p a fire extinguisher
n e a r b y when solvent is used. Use only in well-
v e n t i l a t e d places. Failure to do this may result
i n injury to personnel and damage to equipment.
C l e a n all parts with dry cleaning solvent. Dry with a
Cleaning.
(1)
c l e a n rag.
(2)
Check linkage yokes for cracks. Repair by welding. Refer to TM 9-237.
(3)
I f threads are damaged, get new parts.
C h e c k threads on linkage.
(4)
C h e c k links and mount for cracks.
R e p a i r by welding. Refer to
TM 9-237.
(5)
Check linkage rods for bends. Repair by straightening. Refer
to FM 43-2.
17-694
|