TM 9-2320-211-34-2-3
WARNING
D r y cleaning solvent is flammable. Do not use
n e a r an open flame. K e e p a fire extinguisher
n e a r b y when solvent is used. Use only in well-
Failure to do this may result
ventilated places.
i n injury to personnel and damage to equipment.
M a k e sure that grease passages are
C l e a n i n g . C l e a n all parts with solvent.
d.
D r y all parts well.
open.
Inspection.
e.
FRAME
1
Check that o u t e r boom (1) has no broken welds, and that it is not bent or
1.
damaged.
Check that b o o m sheave pin (2) is not bent or damaged.
2.
Check that t w o pivot pin bushings (3) are not damaged. Check that boom
3.
s h e a v e pin ( 2 ) turns freely but not loosely in pivot pin bushings.
Check that t w o sheave assemblies (4) are not cracked, broken or damaged.
4.
5.
C h e c k that f o u r sheave assembly bearings (5) are not damaged. Refer to
P a r t 1, para 7-7.
GO TO FRAME 2
NOTE
CHECK ONLY THOSE PARTS WHICH ARE CALLED
OUT IN THIS FRAME. PARTS WITHOUT CALLOUTS
ARE SHOWN ONLY FOR REFERENCE PURPOSES
OR ARE CHECKED IN ANOTHER FRAME.