TM 9-2320-211-34-2-3
e.
Inspection.
FRAME
1
1.
U s i n g plug set, s e a l all openings (1) except filter inlet (2).
P u t air hose (3) with proper fitting into filter inlet (2).
2.
3.
P u t oil reservoir (4) into tub filled with water.
WARNING
Eye shields must be worn when using compressed air.
E y e injury can occur if eye shields are not used.
Apply air pressure of five pounds per square inch. Bubbles will show any
4.
l e a k s in oil reservoir (4). M a r k leaking areas for repair.
5.
T a k e oil reservoir (4) out of tub. Take out all seals and take away air hose.
D r y oil reservoir (4) with compressed air at 15 psi max.
6.
GO TO FRAME 2
17-491
|