d. Cleaning, Inspection and Repair.
FRAME
1
WARNING
C l e a n i n g solvent is flammable.  Do not use near an open
flame.  Keep a fire e x t i n g u i s h e r n e a r b y w h e n s o l v e n t i s
u s e d . Use only in w e l l - v e n t i l a t e d places. Failure to
do so may cause damage to equipment and injury to
personnel.
C l e a n all parts with dry cleaning solvent, type II (SD-2), Fed. Spec P-  -D --6 8 0 .
1.
D r y with clean rags.
I f valve adapter is cracked, get
C h e c k that valve adapter (1) is not cracked.
2.
a new one.
I f plug is damaged, get a new one.
Check threads on plug (2).
3.
C h e c k wear on plunger (3) and valve adapter (1).
4.
NOTE
Readings must be within wear limits given in table 17-6.
L indicates a loose fit.  If parts are not within wear
l i m i t s , throw away plunger (3) and valve adapter (1)
a n d get new ones.
END OF TASK
NOTE
CHECK ONLY THOSE PARTS WHICH ARE CALLED OUT.
PARTS WITHOUT CAL LOUTS ARE SHOWN ONLY FOR
REFERENCE PURPOSES.
17-241