TM 9-2320-211-34-2-2
FRAME 3
CAUTION
Be careful when putting on brass fittings. If brass
f i t t i n g s are damaged, they can cause damage to hydrau-
lic pump.
W r a p threads of f i t t i n g s with thread tape.
1.
P u t reducer (1) a n d adapter (2) on elbow (3).
2.
P l a c e preformed p a c k i n g ( 4 ) o n a d a p t e r ( 2 ) .
3.
Put a d a p t e r (2) i n t o h y d r a u l i c p u m p ( 5 ) .
4.
Put o n elbows (6 and 7).
5.
Put h o s e (8) into place and tighten nut (9).
6.
END OF T A S K