TM 9-2320-211-34-2-1
FRAME 2
NOTE
D o not take out alinement pins (1) unless they are dam-
a g e d . Refer to para 9-3e, for inspection procedures.
1.
D r i l l out two alinement pins (1).
NOTE
Do not take out studs (2) unless they are damaged.
Refer to para 9-3e, for inspection procedures.
2.
Take out studs (2).
3.
T a k e o u t two pipe plugs (3).
Take out plugs (4 and 5) with gaskets (6 and 7). Throw away gaskets.
4.
END OF TASK
9-5
|