TM 9-2320-211-34-2-1
FRAME 2
NOTE
M a k e sure that oil has been drained from transfer assembly (1).
1.
U s i n g chain hoist, lift transfer assembly (1) to height for mounting in stand.
2.
M o u n t transfer assembly (1) in stand.
3.
Check that transfer (1) has no leaks around driveshafts (2), shifting fork
pin (3), or sprag air cylinder (4).
WARNING
D r y cleaning solvent is flammable. Do not use near an
o p e n flame. Keep a fire extinguisher nearby when sol-
v e n t is used. Use only in well-ventilated places. Fail-
u r e to do this may result in injury to personnel and
d a m a g e to equipment.
4.
Using solvent, clean outside of transfer assembly (1).
5.
Remove handbrake. Refer to TM 9-2320-211-20.
END OF TASK