TM 9-2320-211-20-3-2
FRAME 2
Aline two mounting holes in circuit breaker (1) with two holes in control
1.
box (2).
2. Push in two screws (3), with two spacers (4). Put on ground wire (5).
3. Using 7/16-inch wrench and screwdriver, screw on and tighten two nuts (6).
NOTE
Follow-on Maintenance Action Required:
Replace heater motor control switch. Refer to para 21-10.
END OF TASK
|