TM 9-2320-211-20-3-2
FRAME 2
1.
Put tube (1) through hole in gondola panel (2).
2.
Using 1 1/2-inch wrench, screw on and tighten coupling nut (3) on
connector (4).
Using 1 1/2-inch wrench, screw in and tighten coupling nut (5) on
3.
pump-to-valve bank hose (6) into other end of tube (1).
4.
Using 1 1/2-inch wrench, tighten coupling nuts (3 and 5).
5 . Replace valve bank cover. Refer to para 18-22.
NOTE
Follow-on Maintenance Action Required:
Fill hydraulic reservoir. Refer to LO 9-2320-211-12.
END OF TASK