TM 9-2320-211-20-3-1
(e) Pipe plug.
CAUTION
Fittings are made of soft brass and can be stripped
easily if tightened too much. Tighten fittings just
enough to stop air from leaking.
NOTE
The pipe plug on the air supply valve is used for
this typical task.
FRAME 1
1.
Screw pipe plug (1) into valve (2).
Using 3/8-inch open end wrench, tighten pipe plug (1).
2*
NOTE
Follow-on Maintenance Action Required:
1. Start engine and let it run until air pressure gage
reads between 65 and 120 psi. Refer to
TM 9-2320-211-10.
2. Stop engine. Refer to TM 9-2320-211-10.
3. Do air system leak test. Refer to para 1-5.
END OF TASK