FRAME 2
Put tube clamp (1) on air tube (2).
1.
NOTE
There may be an electrical harness clamp ( 3). If so,
put harness clamp on capscrew (4) before screwing on
nut (5).  If harness had a plastic tie, put on new tie (6).
Using 7/16-inch wrenches, put capscrew (4) through tube clamp (1) and
2.
screw on and tighten nut (5).
NOTE
Follow-on Maintenance Action Required:
1.
Start engine and let it run until air pressure gage
reads between 65 and 120 psi. Refer to
TM 9-2320-211-10.
2.  Stop engine.  Refer to TM 9-2320-211-10.
3. Do air system leak test. Refer to para 1-5.
END OF TASK
12-127