FRAME 2
WARNING
Be very careful when using jumper wire.  Shorting wire
to ground can burn connector pins or wiring and can
cause injury to personnel.
Push male pin (1) of jumper wire (2) into pin B of generator cable
1.
connector (3).
2.
Push female pin (4) of jumper wire (2) into pin A at battery cable
connector (5).
Lightly touch two ends of jumper wire (2) together. Pull apart immediately.
3.
Disconnect battery ground cable. Refer to para 7-44.
4.
Pull male pin (1) out of generator cable connector (3), and female pin (4)
out of battery cable connector (5).