FRAME 3
NOTE
These steps must be done for any valve where feeler gage
fit is not snug.
Using screwdriver to keep adjusting screw (1) from moving and using 5/8-inch
1.
wrench, loosen locknut (2).
2.
Using screwdriver, turn adjusting screw (1) until feeler gage fit is snug be-
tween rocker arm pad (3) and valve stem (4).
3.
Using screwdriver to keep adjusting screw (1) from moving and using 5/8-inch
wrench, tighten locknut (2).
GO
TO FRAME 5