TM 55-1510-218-MTF
Flap position indicator inoperative.
C38.
a. Tripped circuit breaker.
b. Defective position indicator.
c. Defective position transmitter.
d. Defective wiring.
Pitot tube heater fails to operate
C39.
a. Tripped circuit breaker.
b. Defective heater.
c. Defective wiring.
Stall warning system inoperative.
C40.
a. Defective stall warning switch.
b. Defective stall warning horn.
c. Defective wiring.
Stall warning horn sounds continuously.
C41.
a. Defective stall warning switch.
b. Defective stall warning test system.
c. Defective wiring.
C42. Both inverters inoperative.
a. Tripped inverter circuit breakers (on DC
power distribution panel beneath floor).
b. Defective inverter select switch.
c. Defective wiring in inverter system.
C43. One inverter inoperative.
a. Tripped inverter circuit breaker (on DC
power distribution panel beneath floor).
b. Tripped generator fault circuit breaker.
c. Defective current limiter.
d. Defective inverter.
e. Defective inverter power relay.