TM 55-1510-218-MTF
TROUBLESHOOTING
PROCEDURE
REFERENCE
(9) Standby pump circuit
breakers (Ieft and right) -
In.
(10) Firewall shutoff valve cir-
cuit breakers (Ieft and
right) - In.
(11)
Crossfeed valve switch -
Set alternately to Ieft and
right system. Check that
FUEL CROSSFEED an-
nunciator light illuminates,
and that the #1 and #2
FUEL PRESS annunciator
lights are extinguished.
(12) Crossfeed valve switch -
OFF.
C46, B6-8
*(13) Fuel quantity indicators -
Check as follows:
(a) Fuel quantity indicator
selector
switch
-
MAIN.
(b) Fuel quantity indica-
tors - Compare indica-
tion.
With
full
fuel
tanks, left and right
fuel quantity indicators
must indicate within 82
pounds of each other
with fuel quantity indi-
cator selector switch set
to MAIN.
(c) Fuel quantity indicator
selector switch - AUX-
ILIARY.
(d) Fuel quantity indica-
tors - Compare indi-
2-3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |